 "format": "coredash.scenario/v1",
 "site": "DEMO-01",
 "description": "P-01 Inverter Fault → ปั๊มสำรองรับงานอัตโนมัติ → Reset",
 "loop": true,
 "interpolate": true,
 "settings": {
  "CTRL.sp": 4.0,
  "CTRL.kp": 0.8,
  "CTRL.ti": 3.0,
  "CTRL.deadband": 0.15,
  "CTRL.int_start": 30,
  "CTRL.int_stop": 60,
  "CTRL.alt_hours": 6,
  "CTRL.low_alarm": 3.5,
  "CTRL.high_alarm": 5.5
 },
 "frames": [
  {
   "t": 0,
   "values": {
    "system.pressure": 4.0,
    "FT-01.flow": 115.8,
    "FT-01.total": 128455.4,
    "PM-01.kw": 19.76,
    "PM-01.kwh": 86520.9,
    "PM-01.hz": 50.0,
    "PM-01.pf": 0.93,
    "MCC.phase": 1,
    "MCC.estop": 0,
    "MCC.cab_temp": 34.0,
    "CTRL.lead": 1,
    "CTRL.mode": 0,
    "PM-01.v_l1": 398.8,
    "PM-01.a_l1": 30.3,
    "PM-01.v_l2": 400.0,
    "PM-01.a_l2": 30.7,
    "PM-01.v_l3": 401.2,
    "PM-01.a_l3": 31.0,
    "P-01.freq": 45,
    "P-01.speed": 1332,
    "P-01.current": 36.6,
    "P-01.power": 18.46,
    "P-01.torque": 55.4,
    "P-01.dcbus": 539.1,
    "P-01.vout": 360,
    "P-01.pid_fb": 4.0,
    "P-01.pid_out": 90,
    "P-01.run": 1,
    "P-01.ready": 1,
    "P-01.fault": 0,
    "P-02.freq": 0,
    "P-02.speed": 0,
    "P-02.current": 0,
    "P-02.power": 0,
    "P-02.torque": 0,
    "P-02.dcbus": 540.0,
    "P-02.vout": 0,
    "P-02.pid_fb": 4.0,
    "P-02.pid_out": 0,
    "P-02.run": 0,
    "P-02.ready": 1,
    "P-02.fault": 0
   }
  },
  {
   "t": 40,
   "values": {
    "system.pressure": 4.0,
    "FT-01.flow": 115.8,
    "FT-01.total": 128455.7,
    "PM-01.kw": 19.76,
    "PM-01.kwh": 86520.9,
    "PM-01.hz": 50.0,
    "PM-01.pf": 0.93,
    "MCC.phase": 1,
    "MCC.estop": 0,
    "MCC.cab_temp": 34.0,
    "CTRL.lead": 1,
    "CTRL.mode": 0,
    "PM-01.v_l1": 398.8,
    "PM-01.a_l1": 30.3,
    "PM-01.v_l2": 400.0,
    "PM-01.a_l2": 30.7,
    "PM-01.v_l3": 401.2,
    "PM-01.a_l3": 31.0,
    "P-01.freq": 45,
    "P-01.speed": 1332,
    "P-01.current": 36.6,
    "P-01.power": 18.46,
    "P-01.torque": 55.4,
    "P-01.dcbus": 539.1,
    "P-01.vout": 360,
    "P-01.pid_fb": 4.0,
    "P-01.pid_out": 90,
    "P-01.run": 1,
    "P-01.ready": 1,
    "P-01.fault": 0,
    "P-02.freq": 0,
    "P-02.speed": 0,
    "P-02.current": 0,
    "P-02.power": 0,
    "P-02.torque": 0,
    "P-02.dcbus": 540.0,
    "P-02.vout": 0,
    "P-02.pid_fb": 4.0,
    "P-02.pid_out": 0,
    "P-02.run": 0,
    "P-02.ready": 1,
    "P-02.fault": 0
   },
   "note": "P-01 Fault 2310 (กระแสเกิน)"
  },
  {
   "t": 41,
   "values": {
    "system.pressure": 3.6,
    "FT-01.flow": 0,
    "FT-01.total": 128456.0,
    "PM-01.kw": 1.3,
    "PM-01.kwh": 86521.0,
    "PM-01.hz": 50.0,
    "PM-01.pf": 0.93,
    "MCC.phase": 1,
    "MCC.estop": 0,
    "MCC.cab_temp": 33.1,
    "CTRL.lead": 1,
    "CTRL.mode": 0,
    "PM-01.v_l1": 398.8,
    "PM-01.a_l1": 2.0,
    "PM-01.v_l2": 400.0,
    "PM-01.a_l2": 2.0,
    "PM-01.v_l3": 401.2,
    "PM-01.a_l3": 2.0,
    "P-01.freq": 0,
    "P-01.speed": 0,
    "P-01.current": 0,
    "P-01.power": 0,
    "P-01.torque": 0,
    "P-01.dcbus": 540.0,
    "P-01.vout": 0,
    "P-01.pid_fb": 3.6,
    "P-01.pid_out": 0,
    "P-01.run": 0,
    "P-01.ready": 0,
    "P-01.fault": 2310,
    "P-02.freq": 0,
    "P-02.speed": 0,
    "P-02.current": 0,
    "P-02.power": 0,
    "P-02.torque": 0,
    "P-02.dcbus": 540.0,
    "P-02.vout": 0,
    "P-02.pid_fb": 3.6,
    "P-02.pid_out": 0,
    "P-02.run": 0,
    "P-02.ready": 1,
    "P-02.fault": 0
   }
  },
  {
   "t": 46,
   "values": {
    "system.pressure": 3.2,
    "FT-01.flow": 0.0,
    "FT-01.total": 128456.0,
    "PM-01.kw": 1.9,
    "PM-01.kwh": 86521.0,
    "PM-01.hz": 50.0,
    "PM-01.pf": 0.93,
    "MCC.phase": 1,
    "MCC.estop": 0,
    "MCC.cab_temp": 33.1,
    "CTRL.lead": 2,
    "CTRL.mode": 0,
    "PM-01.v_l1": 398.8,
    "PM-01.a_l1": 2.9,
    "PM-01.v_l2": 400.0,
    "PM-01.a_l2": 2.9,
    "PM-01.v_l3": 401.2,
    "PM-01.a_l3": 3.0,
    "P-01.freq": 0,
    "P-01.speed": 0,
    "P-01.current": 0,
    "P-01.power": 0,
    "P-01.torque": 0,
    "P-01.dcbus": 540.0,
    "P-01.vout": 0,
    "P-01.pid_fb": 3.2,
    "P-01.pid_out": 0,
    "P-01.run": 0,
    "P-01.ready": 0,
    "P-01.fault": 2310,
    "P-02.freq": 30,
    "P-02.speed": 888,
    "P-02.current": 8.9,
    "P-02.power": 0.6,
    "P-02.torque": 2.7,
    "P-02.dcbus": 540.0,
    "P-02.vout": 240,
    "P-02.pid_fb": 3.2,
    "P-02.pid_out": 60,
    "P-02.run": 1,
    "P-02.ready": 1,
    "P-02.fault": 0
   },
   "note": "Failover: P-02 รับงานแทน"
  },
  {
   "t": 70,
   "values": {
    "system.pressure": 3.9,
    "FT-01.flow": 144.9,
    "FT-01.total": 128456.0,
    "PM-01.kw": 23.7,
    "PM-01.kwh": 86521.0,
    "PM-01.hz": 50.0,
    "PM-01.pf": 0.93,
    "MCC.phase": 1,
    "MCC.estop": 0,
    "MCC.cab_temp": 34.2,
    "CTRL.lead": 2,
    "CTRL.mode": 0,
    "PM-01.v_l1": 398.8,
    "PM-01.a_l1": 36.3,
    "PM-01.v_l2": 400.0,
    "PM-01.a_l2": 36.8,
    "PM-01.v_l3": 401.2,
    "PM-01.a_l3": 37.2,
    "P-01.freq": 0,
    "P-01.speed": 0,
    "P-01.current": 0,
    "P-01.power": 0,
    "P-01.torque": 0,
    "P-01.dcbus": 540.0,
    "P-01.vout": 0,
    "P-01.pid_fb": 3.9,
    "P-01.pid_out": 0,
    "P-01.run": 0,
    "P-01.ready": 0,
    "P-01.fault": 2310,
    "P-02.freq": 46,
    "P-02.speed": 1362,
    "P-02.current": 42.7,
    "P-02.power": 22.4,
    "P-02.torque": 65.8,
    "P-02.dcbus": 538.9,
    "P-02.vout": 368,
    "P-02.pid_fb": 3.9,
    "P-02.pid_out": 92,
    "P-02.run": 1,
    "P-02.ready": 1,
    "P-02.fault": 0
   }
  },
  {
   "t": 100,
   "values": {
    "system.pressure": 4.0,
    "FT-01.flow": 115.8,
    "FT-01.total": 128456.4,
    "PM-01.kw": 19.76,
    "PM-01.kwh": 86521.1,
    "PM-01.hz": 50.0,
    "PM-01.pf": 0.93,
    "MCC.phase": 1,
    "MCC.estop": 0,
    "MCC.cab_temp": 34.0,
    "CTRL.lead": 2,
    "CTRL.mode": 0,
    "PM-01.v_l1": 398.8,
    "PM-01.a_l1": 30.3,
    "PM-01.v_l2": 400.0,
    "PM-01.a_l2": 30.7,
    "PM-01.v_l3": 401.2,
    "PM-01.a_l3": 31.0,
    "P-01.freq": 0,
    "P-01.speed": 0,
    "P-01.current": 0,
    "P-01.power": 0,
    "P-01.torque": 0,
    "P-01.dcbus": 540.0,
    "P-01.vout": 0,
    "P-01.pid_fb": 4.0,
    "P-01.pid_out": 0,
    "P-01.run": 0,
    "P-01.ready": 0,
    "P-01.fault": 2310,
    "P-02.freq": 45,
    "P-02.speed": 1332,
    "P-02.current": 36.6,
    "P-02.power": 18.46,
    "P-02.torque": 55.4,
    "P-02.dcbus": 539.1,
    "P-02.vout": 360,
    "P-02.pid_fb": 4.0,
    "P-02.pid_out": 90,
    "P-02.run": 1,
    "P-02.ready": 1,
    "P-02.fault": 0
   }
  },
  {
   "t": 160,
   "values": {
    "system.pressure": 4.0,
    "FT-01.flow": 115.8,
    "FT-01.total": 128456.7,
    "PM-01.kw": 19.76,
    "PM-01.kwh": 86521.1,
    "PM-01.hz": 50.0,
    "PM-01.pf": 0.93,
    "MCC.phase": 1,
    "MCC.estop": 0,
    "MCC.cab_temp": 34.0,
    "CTRL.lead": 2,
    "CTRL.mode": 0,
    "PM-01.v_l1": 398.8,
    "PM-01.a_l1": 30.3,
    "PM-01.v_l2": 400.0,
    "PM-01.a_l2": 30.7,
    "PM-01.v_l3": 401.2,
    "PM-01.a_l3": 31.0,
    "P-01.freq": 0,
    "P-01.speed": 0,
    "P-01.current": 0,
    "P-01.power": 0,
    "P-01.torque": 0,
    "P-01.dcbus": 540.0,
    "P-01.vout": 0,
    "P-01.pid_fb": 4.0,
    "P-01.pid_out": 0,
    "P-01.run": 0,
    "P-01.ready": 1,
    "P-01.fault": 0,
    "P-02.freq": 45,
    "P-02.speed": 1332,
    "P-02.current": 36.6,
    "P-02.power": 18.46,
    "P-02.torque": 55.4,
    "P-02.dcbus": 539.1,
    "P-02.vout": 360,
    "P-02.pid_fb": 4.0,
    "P-02.pid_out": 90,
    "P-02.run": 1,
    "P-02.ready": 1,
    "P-02.fault": 0
   },
   "note": "ช่าง Reset Fault P-01 แล้ว พร้อมเป็นปั๊มสำรอง"
  },
  {
   "t": 240,
   "values": {
    "system.pressure": 4.0,
    "FT-01.flow": 115.8,
    "FT-01.total": 128457.0,
    "PM-01.kw": 19.76,
    "PM-01.kwh": 86521.2,
    "PM-01.hz": 50.0,
    "PM-01.pf": 0.93,
    "MCC.phase": 1,
    "MCC.estop": 0,
    "MCC.cab_temp": 34.0,
    "CTRL.lead": 2,
    "CTRL.mode": 0,
    "PM-01.v_l1": 398.8,
    "PM-01.a_l1": 30.3,
    "PM-01.v_l2": 400.0,
    "PM-01.a_l2": 30.7,
    "PM-01.v_l3": 401.2,
    "PM-01.a_l3": 31.0,
    "P-01.freq": 0,
    "P-01.speed": 0,
    "P-01.current": 0,
    "P-01.power": 0,
    "P-01.torque": 0,
    "P-01.dcbus": 540.0,
    "P-01.vout": 0,
    "P-01.pid_fb": 4.0,
    "P-01.pid_out": 0,
    "P-01.run": 0,
    "P-01.ready": 1,
    "P-01.fault": 0,
    "P-02.freq": 45,
    "P-02.speed": 1332,
    "P-02.current": 36.6,
    "P-02.power": 18.46,
    "P-02.torque": 55.4,
    "P-02.dcbus": 539.1,
    "P-02.vout": 360,
    "P-02.pid_fb": 4.0,
    "P-02.pid_out": 90,
    "P-02.run": 1,
    "P-02.ready": 1,
    "P-02.fault": 0
   }
  }
 ]
}